Lo-Carbon Solo Plus

Description

Overview

The Lo-Carbon Solo Plus range from Vent-Axia has been specially designed for through the wall and ducted applications, suitable for internal bathrooms, WC’s and other small rooms. Finished in white, the Lo-Carbon Solo Plus can be flush or surface mounted, with a 2-position 100mm circular spigot for rear entry or connecting to a vertical ducting system. The new Lo-Carbon Solo Plus has an adjustable boost speed which is set at installation variable between 57-105m3/h for boost/override operation to meet Building Regulations thus ensuring minimum energy usage and low sound levels. All models have an optional speed for constant trickle ventilation (25m3/h), selectable at installation. Depending on the model, the fan will switch from trickle (if selected) to boost via the pullcord/light switch/humidity sensor/PIR. Four models are available offering features such as, Pullcord, Timer, Humidistat/Timer or PIR versions. All models can be wall; panel or ceiling mounted and can be connected to either circular, rectangular or Vent-Axia’s System 25 flat ducting, which has been specially designed for concealed applications that can benefit from its ultra slim 25mm depth. Cable entry is achieved through a rear entry grommet on the top right hand side of the unit. Enclosure of the electrical components is manufactured from flame retardant grade material. Supply voltage 220-240V/1/50Hz. Motor Incorporated into the Lo-Carbon Solo Plus is a highly efficient DC long life ball bearing motor. DC motors offer the benefit of over 80% efficiency over conventional shaded pole motors within their class. The fully enclosed motor is fixed onto a 3 position anti-vibration mount which offers higher reliability and lower noise.

Model Range


 
Lo-Carbon Solo Plus P (Pullcord)
Flush or surface mountable. Control by Pullcord. 2 Speed. Constant trickle option. Adjustable boost. In-built Lo-Carbon controller.
Stock Ref No: 427481A
 
Lo-Carbon Solo Plus T (Timer)
Flush or surface mountable. Control by room light or switch. 2 Speed. Constant trickle option. Adjustable boost. Adjustable timer overrun. Delay on timer. In-built Lo-Carbon controller.
Stock Ref No: 427482A
 
Lo-Carbon Solo Plus HT (Humidistat/timer)
Flush or surface mountable. Humidity controlled 2 speed fan. Constant trickle option. Adjustable timer overrun. Delay on timer. Adjustable humidity sensor. With pullcord override.
Stock Ref No: 427483A
 
Lo-Carbon SOLO PLUS TM (Timer/PIR)
Flush or surface mountable. Control by integral PIR detector. 2 Speed. Constant trickle option. Adjustable boost. In-built LoCarbon controller.
Stock Ref No: 427484A

Product Specification


Type: Lo-Carbon Solo Plus P Lo-Carbon Solo Plus T Lo-Carbon Solo Plus HT Lo-Carbon Solo Plus TM
Stock Ref No: 42 74 81 42 74 82 42 74 83 42 74 84
High: 105 105 105 105
Extract Perf. (m³/h) Med: 57 57 57 57
Low: 25 25 25 25
High: 21 21 21 21
Watts Med: 6.5 6.5 6.5 6.5
Low: 5.3 5.3 5.3 5.3
Sound dB(A) @ 3m High: 42.8 42.8 42.8 42.8
Trickle: 23.7 23.7 23.7 23.7

 

Performance

 
 
 
Flush fitted model
Surface mounted model
Washable removable filter
 



 

Dimensions

 

Can be installed either as recess or surface mounted as standard. No other accessories are required.
NOTE: The transformer is an integral part of the fan which MUST NOT be installed as a SELV product.


A B C D F G H I J K L
261 221 107 54.5 98 64 61 253 208 37 98 70
Solo + LoWatt Weight 2.2kg

 

Typical Specifications

Supply and Install a Lo-Carbon Solo Plus Centrifugal fan as supplied by

Vent-Axia Ltd
Fleming Way
Crawley
West Sussex
RH10 9YX
Telephone: 01293 526062.

The fan should be suitable for flush or surface mounting, for wall, panel and ducted applications. The fan should have a 100mm spigot with integral backdraught shutter capable of changing its orientation to receive rear entry or vertical ducting. The fan should be able to offer constant trickle ventilation boosted by various integral sensors.

The fan should be double insulated and meet the Building Regulation (Document F) requirements of 15 litres a second for bathrooms and 6 litres a second for toilets.

The electronically controlled DC motor is fitted with long life ball bearings to provide an expected 40,000 hour running life and a Standard Thermal Overload Protection (S.T.O.P.). The motor should be insulated to Class III and conform to BS EN 60335-2-80.

Operation via pullcord/light switch or integral overrun timer. IPX4rated.

The fan is to be wall mounted using a wall kit 25 41 00 (brown) or 25 41 02 (white) or window mounted using 114 61 685A.

There are no softwares available for download for this particular product.