This ever popular range of extract/intake ventilating units continues to satisfy the most demanding requirements of efficient ventilation. The Standard range unit is supplied without a shutter. The shutter is available as an accessory which can be easily fitted within the unit.

Standard range fans are suitable for most forms of single glazing or can be wall mounted in a Vent-Axia fixing plate. Vent-Axia's patented spigot and ring method of fixing ensures easy installation and weather proof joint. The simple integrated component design makes installation and servicing easy.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools

Protective Grilles

Where Standard range units are installed in low positions, finger guards provide extra protection to VDE, DIN 31001.

Model Range

Standard Range Window Model S6WW
Classic Retro-Style Ventilation This ever popular range of extract/intake ventilating units continues to satisfy the most demanding requirements for efficient ventilation. The Vent-Axia Standard Range unit is supplied without a shutter. The shutter is available as an accessory, which can be easily fitted within the unit.
Stock Ref No: 131310B
 
Standard Range Window Model S7WW
Classic Retro-Style Ventilation This ever popular range of extract/intake ventilating units continues to satisfy the most demanding requirements for efficient ventilation. The Vent-Axia Standard Range unit is supplied without a shutter. The shutter is available as an accessory, which can be easily fitted within the unit.
Stock Ref No: 132310B
 
Standard Range Window Model S9WW
Classic Retro-Style Ventilation This ever popular range of extract/intake ventilating units continues to satisfy the most demanding requirements for efficient ventilation. The Vent-Axia Standard Range unit is supplied without a shutter. The shutter is available as an accessory, which can be easily fitted within the unit.
Stock Ref No: 133310B
 
Standard Range Window Model S12WW
Classic Retro-Style Ventilation This ever popular range of extract/intake ventilating units continues to satisfy the most demanding requirements for efficient ventilation. The Vent-Axia Standard Range unit is supplied without a shutter. The shutter is available as an accessory, which can be easily fitted within the unit.
Stock Ref No: 134310B

Accessories

 
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Stock Ref No: W362320
 
Ambient Response Humidity Sensor
The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Can be wired into controller "Auto" mode connections. Night time RH increment setback feature suppresses uisance tripping when the humidity level gradually rises as the temperature falls. Features & Benefits:
  • Ambient operating temp range +5°C to +40°C.
  • Changeover relay switch.
Stock Ref No: 563550A
 
Air Quality Sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms.
Stock Ref No: 563506B
 
Ecotronic Humidity Sensor
An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90%RH. Can be wired into controller "Auto" mode connections. Incorporates changeover switch to select low/high speed.Features & Benefits:
  • Ambient operating temp range 0°C to +40°C.
  • BEAB Approved.
  • Dimensions: 87 x 87 x 33mm (H x W x D).
  • Maximum switching load 1 amp inductive.
  • Pullcord override indicated by lamp.
  • Setting Range: 65% - 90%RH.
Stock Ref No: 563532A

Product Specification

Motor

Purpose designed enclosed motor. Suitable for running at any angle. Quiet running, enclosed.

Supply voltage 220-240V/1/50 Hz.
Suitable for operation in ambient temperatures from -40° to +50°C. Fitted with Standard Thermal Overload Protection (S.T.O.P.).

Shutter

Type SD/R. This extract/intake shutter fits inside the Vent-Axia unit and closes against unwanted backdraughts. It can be fitted at the same time as the unit or at a later date if required.

Airflow operated for extract use, cord operated lock for intake use. For all models mounted in vertical surfaces.


Unit size 6 7 9 12
Type S6/WW S7/WW S9/WW S12/WW
Stock Ref. No. 13 13 10 13 23 10 13 33 10 13 43 10
Amps @ 240V 0.16 0.16 0.24 0.36
Extract Perf MAX m³/h 285 425 710 1560
Watts MAX. 32 34 53 84
dB(A) (med) @ 3m 35 31 39 42
Shutter Type SD/R 23 17 10 23 27 10 23 37 10 23 47 10
Range-master
RVS Surface W30 01 10 W30 01 10 W30 01 10 W30 01 10
Flush Fitting W30 01 10 W30 01 10 W30 01 10 W30 01 10
+ 40 01 44 + 40 01 44 + 40 01 44 + 40 01 44
Time Switch Type TTC W36 13 10 W36 13 10 W36 13 10 W36 13 10
Multi-unit Type MUC W36 23 10 W36 23 10 W36 23 10 W36 23 10

 
[^Top of page]

Dimensions


Impeller dia. 150mm 190mm 230mm 300mm
A 140 147 166 201
216 254 295 381
C 21 21 21 21
D 83 83 92 105
E (max) 10 10 10 13
Fixing hole dia. 184 222 260 337
Weight 2.9kg 3.2kg 4.6kg 7.0kg

 



 
[^Top of page]

Typical Specifications

Supply and install a Standard Range Window fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293 526062.

The fan should be suitable for all forms of single glazing, including wire cast, reeded, leaded lights and fixing plates up to 10mm thick.

The fan should have the option of a backdraught shutter.

The fan should be fully reversible and be able to be controlled by using variable speed controllers or by humidity, air quality or TimeSwitches.

The unit should meet with Document F of the Building Regulations.

The motor should be suitable for mounting at any angle and suitable for operation in ambient temperatures from -40°C to +50°C and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).


 

There are no softwares available for download for this particular product.