T-Series Panel and Ceiling Model

Description

Overview

T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvred grilles, through external walls. When installed only the louvred grille is visible. The range features a unique speed control pack which enables high, medium or low speed to be preset to suit a specific room size or required duty.

T-Series controllers may be used with this model to obtain a choice of speeds, reversible airflow direction and automatic sensor operation. When used with a controller, the speed control pack is removed from the T-Series ventilating unit and fitted into the 3-pin socket in the back of the controller. The Vent-Axia Ecotronic controller gives even greater running economy with its minimum speed setting on 'E' mode and infinitely variable speed control. For this controller the speed control pack remains in the fan.

Easy Cleaning

Integrated component design allows all parts to be dismantled for cleaning without the use of specialist tools.

Model Range

TX6PL
T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvred grilles, through external walls. When installed only the louvred grille is visible.
Stock Ref No: W161610B
 
TX7PL
T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvred grilles, through external walls. When installed only the louvred grille is visible.
Stock Ref No: W162610B
 
TX9PL
T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvred grilles, through external walls. When installed only the louvred grille is visible.
Stock Ref No: W163610B
 
TX12PL
T-Series panel/ceiling models are suitable for mounting at any angle in internal partitions, ceilings, ducts and, with louvred grilles, through external walls. When installed only the louvred grille is visible.
Stock Ref No: W164610B

Accessories

 
T-Series Controller
  • Three speeds. Choice of extract/intake
  • Shutter open, fan Off setting
  • Sensor mode. Enables external electro mechanical switches, eg:
Ecotronic, HumidiSwitch, ThermoSwitch and TimeSwitch to control the fan.
Stock Ref No: W361119
 
Ecotronic Controller
For groups of units of any one size up to a total of 400 watts. Do not mix T-Series with Standard Range ventilating units on one controller.
Stock Ref No: W362320
 
Air Quality Sensor
Automatically reacts to the depletion of air quality, sensing tobacco smoke, smells and toilet odours to regulate mechanically ventilated areas such as cinemas, pubs, clubs, restaurants, kitchens, toilets and conference rooms.
Stock Ref No: 563506B
 
Ambient Response Humidity Sensor
The latest self programming electronic On/Off wall mounted humidity sensor which reacts to any rapid increase in humidity and temperature by switching a Vent-Axia fan ‘On’ for rapid removal of moisture laden air, in domestic bathrooms and kitchens. Can be wired into controller "Auto" mode connections. Night time RH increment setback feature suppresses uisance tripping when the humidity level gradually rises as the temperature falls. Features & Benefits:
  • Ambient operating temp range +5°C to +40°C.
  • Changeover relay switch.
Stock Ref No: 563550A
 
Ecotronic Humidity Sensor
An adjustable set point, solid state On/Off sensor. A pullcord provides manual override, indicated by lamp. Adjustable from 65 to 90%RH. Can be wired into controller "Auto" mode connections. Incorporates changeover switch to select low/high speed.Features & Benefits:
  • Ambient operating temp range 0°C to +40°C.
  • BEAB Approved.
  • Dimensions: 87 x 87 x 33mm (H x W x D).
  • Maximum switching load 1 amp inductive.
  • Pullcord override indicated by lamp.
  • Setting Range: 65% - 90%RH.
Stock Ref No: 563532A

Product Specification

Shutter

With energy saving in mind TX models are supplied complete with an integral instantaneous automatic louvre shutter concealed behind the interior grille. It will operate on both intake and extract and at any angle of mounting.

The shutter is electronically controlled by an actuator with a damped action giving quiet instant operation during instant opening and closing. The interlocking edges of the shutter blades provide maximum backdraught protection.

When the ventilating unit is used with a T-Series controller, the shutter can be set open with the fan motor switched Off to provide natural ventilation without the security risk of an open window.

TL models do not have a shutter. They are suitable for certain ducted applications, room to room systems and where there is a need for ventilation of specialised equipment. The TL model will also provide natural ventilation where required when the unit is switched Off.

Electrical

Suitable for operation in ambient temperatures from -40°C to +50°C.

Fitted with self resetting Standard Thermal Overload Protection (S.T.O.P).

Supply voltage:
220-240V/1/50Hz (120V/1/60 Hz).


Unit size 6
Type TX6PL TL6PL
Stock Ref. No. W16 16 10 W26 16 10
Amps @ 240V 0.24 0.21
Extract Performance m³/h Low 295
Extract Performance m³/h Med 380
Extract Performance m³/h High 435
Watts (high) 45 40
dB(A) (med) @ 3m 41
Shutter (TX only) Instant
Surface Controllers T-Series Type TSC W36 11 19
Surface Controllers Ecotronic 130 W30 01 20
Surface Controllers Ecotronic 400 W36 23 20
Surface Controllers Time Switch TTC W36 13 10


Unit size 7
Type TX7PL TL7PL
Stock Ref. No. W16 26 10 W26 26 10
Amps @ 240V 0.24 0.21
Extract Performance m³/h Low 365
Extract Performance m³/h Med 480
Extract Performance m³/h High 585
Watts (high) 46 41
dB(A) (med) @ 3m 37
Shutter (TX only) Instant
Surface Controllers T-Series Type TSC W36 11 19
Surface Controllers Ecotronic 130 W30 01 20
Surface Controllers Ecotronic 400 W36 23 20
Surface Controllers Time Switch TTC W36 13 10


Unit size 9
Type TX9PL TL9PL
Stock Ref. No. W16 36 10 W26 36 10
Amps @ 240V 0.42 0.39
Extract Performance m³/h Low 565
Extract Performance m³/h Med 830
Extract Performance m³/h High 960
Watts (high) 80 75
dB(A) (med) @ 3m 43
Shutter (TX only) Instant
Surface Controllers T-Series Type TSC W36 11 19
Surface Controllers Ecotronic 130 W30 01 20
Surface Controllers Ecotronic 400 W36 23 20
Surface Controllers Time Switch TTC W36 13 10


Unit size 12
Type TX12PL TL12PL
Stock Ref. No. W16 46 10 W26 46 10
Amps @ 240V 0.51 0.48
Extract Performance m³/h Low 1270
Extract Performance m³/h Med 1640
Extract Performance m³/h High 1885
Watts (high) 105 100
dB(A) (med) @ 3m 44
Shutter (TX only) Instant
Surface Controllers T-Series Type TSC W36 11 19
Surface Controllers Ecotronic 130 W30 01 20
Surface Controllers Ecotronic 400 W36 23 20
Surface Controllers Time Switch TTC W36 13 10

Performance

 



 

Dimensions


Size 6 (150mm) 7 (190mm) 9 (230mm) 12 (300mm)
A 310 352 391 470
B 303 345 388 467
C 117 117 129 152
D 32 32 39 41
E 220 258 302 378
F 226 265 304 381
180 218 255 334
171 210 247 325
J 267 306 345 422
K 231 270 309 386
L 244 282 326 402
M 85 104 126 164
Weight (kg) 3.50 3.82 5.13 7.44

 



 

Typical Specifications

Supply and install a T-Series Panel/Ceiling fan as manufactured by Vent-Axia Ltd, Fleming Way, Crawley, West Sussex, RH10 9YX Telephone: 01293526062.

The fan should be suitable for installation at any angle in partitions, ceilings and ducts. The unit should flush mounting so that only the louvered grille is visible when installed.

The fan should have a speed control pack which enables high, medium and low speed to be set to suit room size or required duty.

The fan should be fully reversible and be able to be controlled by using variable speed controller or by humidity, air quality or PIR sensors.

The fan should incorporate an electronically controlled instantaneous shutter mechanism that has a facility to be in an open state without the fan running for passive ventilation.

The unit should meet with Document F of the Building Regulations and be BEAB approved.

The motor should be suitable to run at any angle and suitable for operation in ambient temperatures from -40°C to +50°C. and should be fitted with self resetting Standard Thermal Overload Protection (S.T.O.P.).

Patented Shutter Actuator System
European Patent Number EP 0177215

Patented Remote Speed Control Circuit
European Patent Number EP 0180311.