VA 100 Range

Description

Overview

The VA100 range from Vent-Axia is designed for domestic bathrooms and WC's. Available as window, wall or panel mounted models. A range of fans with options of shutter, timer or humidity controlled versions.

The VA100 meets and exceeds the Building Regulation (Document F) requirements of 15 l/s for domestic bathrooms with integral WC's. Designed in a clean white finish. Suitable for ambient temperatures up to +40°C fitted with ball bearing motors. IPX4 Rated.

Model Range

 
VA100LT (Timer)
Bathroom and WC fan with adjustable electronic overrun timer and neon light.
Stock Ref No: 251210B
 
VA100XP (Pullcord/Shutter)
Bathroom fan with thermo-electric shutter, pullcord and neon light.
Stock Ref No: 251310C
 
VA100XT (Timer/Shutter)
Bathroom fan with adjustable electronic overrun timer, thermoelectric shutter and neon light.
Stock Ref No: 251410C
 
VA100LHP (Humidistat/Pullcord)
Bathroom fan with presettable integral auto humidity control, neon running light and pullcord.
Stock Ref No: 251610E
 
VA100XHP (Humidistat/Pullcord/Shutter)
Bathroom fan with presettable integral auto humidity control, thermo-electric shutter, neon running light and pullcord.
Stock Ref No: 251710F
 
VA100XHT (Humidistat/Timer/Shutter)
Bathroom fan with presettable integral auto humidity control and adjustable electronic overrun timer, thermo-electric shutter and neon light.
Stock Ref No: 251510B


Accessories

 
Quick fix 100mm Wall Grille (Ivory)
Quick fix 100mm Wall Grille (Ivory)
Stock Ref No: 563521
 
 
100mm Wall Fitting Kits (White)
100mm Wall Fitting Kits (White) For installing into most walls using the telescopic liners supplied.
Stock Ref No: 254102
 
100mm Window Fitting Kit
Window kit available for use in single or sealed double glazing and where sunstrate is up to 40mm thick. A simple to install window kit manufactured from durable ABS and compatable with 100mm VA100 axial fan
Stock Ref No: 254101A
 

Product Specification

VA100 models are fitted with an electronic timer which provides the necessary 15 minute overrun time to comply with Building Regulation (Document F) requirements for internal WC ventilation. Adjustable from 3-20 minutes.

To meet IEE Regulations, timer models should be isolated using a 3 pole isolator.
Stock Ref. No. 56 35 18


Type Stock ref. no. Window kit White grille wall kit Brown Grille Wall kit
VA100LP 25 11 10B 25 41 01 25 41 02 25 41 00
VA100LT 25 12 10B 25 41 01 25 41 02 25 41 00
VA100XP 25 13 10C 25 41 01 25 41 02 25 41 00
VA100XT 25 14 10C 25 41 01 25 41 02 25 41 00
VA100LHP 25 16 10E 25 41 01 25 41 02 25 41 00
VA100XHP 25 17 10F 25 41 01 25 41 02 25 41 00
VA100XHT 25 15 10B 25 41 01 25 41 02 25 41 00


Type Stock Ref. No. Extract Performance m³/h l/s Watts dB(A) @ 3m Shutter
VA100LP 25 11 10 90 25 15 32
VA100LT 25 12 10 90 25 15 32
VA100XP 25 13 10 90 25 20 32 Thermo
VA100XT 25 14 10 90 25 21 32 Thermo
VA100LHP 25 16 10C 90 25 16 32
VA100XHP 25 17 10 90 25 21 32 Thermo
VA100XHT 25 15 10 90 25 21 32 Thermo

 

Performance

 


VA100 performance
VA100 performance

 

Dimensions


A B C D E F G
mm 155 44 56 98 32 89 200
Transformer 148 87 19 49

 

Wall model dimensions
Fixing hole diameter 117mm
Fixing hole diameter 117mm

 

Window model dimensions
Fixing hole diameter 105mm
Fixing hole diameter 105mm

 

Panel model dimensions
Fixing hole diameter 105mm
Fixing hole diameter 105mm

 

Typical Specifications

Supply and install a VA100 mains axial fan suitable for mounting in panels, walls or windows, with thermally operated backdraught shutter (X, XT, XH and XHT models only), removable grille and fan running light as supplied by:


The fan performance should meet the Building Regulation (Document F) requirements of 15 litres a second for bathrooms and 6 l/s for toilets,(15 minute timer overrun model for internal WC’s).

The fan should have a ball bearing motor for installation at any angle. The motor should be insulated to Class B.

Operations  
VA100LP - via light switch with pullcord
VA100XP - via light switch with pullcord and shutters
VA100LT - via light switch with timer overrun facility
VA100XT - via light switch with timer overrun facility and shutters
VA100LHP - via light switch with integral humidity sensor and pullcord fan override
VA100XHP - via light switch with integral humidity sensor and pullcord fan override with shutters
VA100XHT - via integral humidity sensor/timer overrun facility with shutters.
 
 
115mm hole is drilled with a core cutter when using a wall fitting kit.
Then the telescopic wall liner is fitted

There are no softwares available for download for this particular product.